Elitech PDF Temperature Data Logger, RC-4 Specification

  • Data Capacity
  • 16000 points
  • Theory
  • Electronic Data Recording
  • Alarm
  • Programmable high/low temperature alarm
  • Temperature Range
  • -30C to +60C
  • Power Supply
  • 3V Lithium Battery (CR2450)
  • Type
  • PDF Temperature Data Logger
  • Display Type
  • LCD
  • Memory
  • 16000 readings
  • Accuracy
  • 0.5C (-20C to +40C), 1.0C (others)
  • Size
  • 84mm x 44mm x 19mm
  • Resolution
  • 0.1C
  • Battery
  • CR2450 coin cell (replaceable)
  • GPS
  • No
  • Net Weight
  • Approx. 40g
  • Standby Time
  • About 6 months
  • Interface
  • USB
  • Measuring Range
  • -30C to +60C
  • Includes
  • 1 x Data Logger, 1 x USB Cable, User Manual
  • Software Requirement
  • No software required for PDF report generation
  • Application
  • Cold chain, food, medicine, logistics, and warehouse monitoring
  • Operating Environment
  • Temperature: -30C to +60C; Humidity: 10%~90%RH
  • Data Output
  • Automatic PDF report via USB
  • Sensor Type
  • Internal NTC thermistor
  • Stop Mode
  • Button, software, or memory full
  • Sampling Interval
  • 10 seconds to 24 hours, programmable
  • Waterproof Level
  • IP67
  • Start Mode
  • Button or software
 

Elitech PDF Temperature Data Logger, RC-4 Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Delivery Time
  • 2 Days
 

About Elitech PDF Temperature Data Logger, RC-4

True Sense Elitech RC-4 Temperature Data Logger is a high-precision device designed for reliable temperature monitoring in cold chain, medical, food, and industrial applications.

It features a wide measurement range, large memory capacity, and USB connectivity for easy data transfer. With an LCD display and automatic PDF/Excel report generation, it simplifies tracking and documentation. The replaceable battery ensures long-term, uninterrupted operation.


Applications: Cold chain transport, laboratories, food storage, medical facilities, and industrial environments requiring precise temperature monitoring.


Features of Elitech RC-4 Data Logger:

  • High-precision temperature measurement

  • Wide measurement range suitable for various applications

  • Large memory capacity for extensive data logging

  • USB connectivity for easy data export

  • LCD display for clear readings

  • Automatic PDF/Excel report generation for documentation

  • Replaceable battery for long-term use



Easy, Software-Free Data Reporting

With its built-in USB interface, the Elitech RC-4 automatically generates comprehensive PDF temperature reports upon connection to a computer-no additional software required. This plug-and-play functionality streamlines data access, making it ideal for quick inspections and audits in logistics, cold chain, and storage operations.


Accurate and Programmable Monitoring

Equipped with an advanced internal NTC thermistor, the RC-4 data logger ensures a high degree of accuracy at 0.5C within critical temperature ranges. Users can select sampling intervals from 10 seconds to 24 hours, tailoring data collection to match precise monitoring requirements across various industries and applications.


Robust Design for Demanding Environments

Protected with an IP67 waterproof rating, the Elitech RC-4 is suited for use in harsh or humid environments, including refrigerated transport and storage. The device is compact, lightweight, and features an easily replaceable CR2450 battery, ensuring long standby times and consistent performance wherever precise temperature logging is needed.

FAQ's of Elitech PDF Temperature Data Logger, RC-4:


Q: How do I start and stop the temperature recording on the Elitech RC-4?

A: You can start recording with either the physical button on the logger or by using dedicated software. To stop logging, press the button, use the software, or allow the device to stop automatically when its memory is full.

Q: What kind of data output is provided by this temperature data logger?

A: The RC-4 outputs data as an automatic PDF report when you connect it to a computer via USB. No software installation is required-simply plug in and access your detailed temperature records.

Q: Where can the Elitech RC-4 data logger be used effectively?

A: This device is ideal for cold chain logistics, pharmaceuticals, food safety monitoring, warehousing, and any application requiring accurate temperature data tracking between -30C and +60C, even in humid or wet conditions thanks to its IP67 waterproof rating.

Q: What is the process for retrieving stored temperature data from the logger?

A: Connect the logger to a PC using the provided USB cable. The device will generate and open a PDF report automatically, displaying all saved temperature readings, alarm events, and statistics for your analysis.

Q: What is the benefit of having a programmable sampling interval?

A: A programmable sampling interval (from 10 seconds to 24 hours) allows users to balance data granularity and device memory usage, optimizing the monitoring process for both short-term shipping and long-term storage scenarios.

Q: How many temperature readings can the Elitech RC-4 store, and what happens when memory is full?

A: The device can store up to 16,000 readings. Once its memory is full, recording will automatically stop to prevent data overwriting, and the logger will indicate it is ready for data retrieval and reset.

Q: When should I replace the battery in my Elitech RC-4 logger?

A: The RC-4 uses a CR2450 coin cell battery, providing about 6 months of standby time. Replace the battery when the display shows low power, or if the logger ceases to record or generate reports as expected.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Data Loggers Category

True Sense Tzone TempU09 90 Days Single Use USB Temperature Data Logger with LCD Display, TempU09

True Sense Tzone TempU09 90 Days Single Use USB Temperature Data Logger with LCD Display, TempU09

Price 950.0 INR / Piece

Minimum Order Quantity : 1 Piece

Display Type : Other, LCD Display

Type : Other, Single Use USB Temperature Data Logger

Resolution : 0.1C

Data Capacity : 32,000 readings

True Sense USB Temperature & Humidity Data Logger Recorder Tester Pen, HT-160

True Sense USB Temperature & Humidity Data Logger Recorder Tester Pen, HT-160

Price 2250.0 INR / Piece

Minimum Order Quantity : 1 Piece

Display Type : Other, LED Indicator

Type : Other, USB Temperature & Humidity Data Logger Tester Pen

Resolution : Temperature: 0.1C, Humidity: 0.1%RH

Data Capacity : 16000 (Temperature) + 16000 (Humidity)

True Sense 60 Days Temperature Data Logger Disposable Temperature Recorder, TempU02-60

True Sense 60 Days Temperature Data Logger Disposable Temperature Recorder, TempU02-60

Price 600.0 INR / Piece

Minimum Order Quantity : 5 Pieces

Display Type : Other, LED Indicator

Type : Other, Disposable Temperature Data Logger

Resolution : 0.1C

Data Capacity : 16,000 data points

True Sense Temperature Data-Logger For Monitoring, Food Applications, Storage, Refrigerators, TempU04

True Sense Temperature Data-Logger For Monitoring, Food Applications, Storage, Refrigerators, TempU04

Price 1800.0 INR / Piece

Minimum Order Quantity : 1 Piece

Display Type : Other, LCD Display

Type : Temperature Data Logger

Resolution : 0.1C

Data Capacity : 16000 Temperature Readings



Back to top